12. Procedure to change the pump gland packing. MEO 5 Oral
MEO CLASS 4 & 5 COMBINED
Sample Oral Question Bank by DoS Bangladesh
Procedure to change the pump gland packing.
Ans:
i)
Ensure the
packing is damage or has lost its properties.
ii) Remove gland follower nut & pull back the
gland follower.
iii) Remove packing & lantern ring by using
gland extractor. Care required to being damage of stuffing box wall.
iv) Clean the housing carefully & inspect the
shaft if there any damage
v) Select packing according to the manufacture.
(Or measure shaft diameter & stuffing box inner diameter by substitute get
the packing diameter, measure stuffing box depth to know how many packing
required.)
vi) Cut the packing with a sharp knife straight or
45 degree angle to make ring.
vii) Place the first packing ring & place it around
the shaft & verify that the end of packing joine.
viii) Place all the packing & lantern ring as they
were previously.
ix) Take gland follower & press the ring into position.
x) Now tightening the gland follower with nut but
over tightening may result in over temp so loose the nut & tight again with
finger.
xi) Adjustment may require while the pump is in operation.